The improvement information on TELLUS and V-Server is published.

Improvement information Improvement information list

Version retrieval

Keyword retrieval

TELLUS
◆Ver. 5
No. Item Description Altered
Ver.
Correction
Ver.
25B0X01 Overlap display Fixed the defect: An overlap is not displayed when a multi overlap display button is pressed after file selection for logging/alarms, filtering, or displaying the recipe selection window on the emulator for TELLUS Ver. 5 or V10. 5.0.3.0
25B0X02 Hard copy Fixed the defect: When a hard copy is made with the orientation of the document set to landscape in the print settings of TELLUS version 4.0.22.0 or later, the actual copy is output in portrait orientation. 5.0.3.0
25B0X03 Overlap display Fixed the defect: If an overlap display is continuously shown or hidden at short intervals, the actual display status of the overlap display and the registration/display status of the system device memory may become inconsistent. 5.0.3.0
25B0X04 Macro commands Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. 5.0.3.0
25B0X05 Lamps Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. 5.0.3.0
25B0Y01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.710 5.0.3.0
25B0Y02 MITSUBISHI ELECTRIC: FX5U/5UC series
MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet)
Fixed the defect: When communication exceeding the maximum I/O points of the PLC's specification is attempted for multiple batch block write commands, a communication error occurs. 1.610
1.710
5.0.3.0


◆Ver. 4/Ver. 3
No. Item Description Altered
Ver.
Correction
Ver.
25B0Q01 Hard copy Fixed the defect: When a hard copy is made with the orientation of the document set to landscape in the print settings of TELLUS version 4.0.22.0 or later, the actual copy is output in portrait orientation. 4.0.24.0
25B0Q02 Macro commands Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. 4.0.24.0
25B0Q03 Lamps Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. 4.0.24.0
25B0R01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.710 4.0.24.0
25B0R02 MITSUBISHI ELECTRIC: FX5U/5UC series
MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet)
Fixed the defect: When communication exceeding the maximum I/O points of the PLC's specification is attempted for multiple batch block write commands, a communication error occurs. 1.610
1.710
4.0.24.0


V-Server

No. Item Description Altered
Ver.
Correction
Ver.
25B0S01 Loading recipes Fixed the defect: V-Server may be forcibly terminated if loading of a recipe is executed using an Excel file containing an error in a cell. 5.0.3.0